New Products

NewTom 5G ConeBeam CT
Latest 5th Generation Cone Beam CT, first horizontal...

GLOBAL LED Light Source
Is a no-maintenance, low cost, long lasting light source...

Imax Touch '3 in 1' Imaging System
Combining 3 Panoramic, Cephalometric and CB3D...

ECLERIS Colposcope
Covering all the diagnosis and therapeutic needs in modern gynecology...

Newtom 5G Cone Beam CT

Newtom 5G

The Newtom 5G is the latest Cone Beam System to be released by QR Systems in Italy. The flat panel technology of the 5G produces exceptionally high resolution images with 6 programmable fields of view ranging from 6x6cm to 18x16cm. Utilizing the patented "Smart Scan" technology, patient radiation dose levels are kept to an absolute minimum with all exposure settings controlled automatically. Perfect image exposure from small infants through to large adults is guaranteed every time.

The Newtom 5G is configured as a horizontal system and is ideally suited to patients who are unable to remain stationary in a vertical position during the scan. This could include sedated patients, trauma cases, infants, geriatrics and special needs patients. The 'pass through' gantry design also allows other extremities such as hands, ankles, feet, elbows and knees to be scanned with hard tissue image quality equivalent to traditional CT scans.

Download Flyer

Features

Features of the Newtom 5G

  • Flat panel sensor technology.
  • Safe beam exposure control.
  • Seated or horizontal patient entry.
  • Horizontal scan position for sedated & trauma patients and infants.
  • Six programmable 'Fields of View' from 6x6cm to 18x16cm.
  • Lowest Dose of any comparable CBCT on the market.
  • Pass through gantry allowing other body extremities to be scanned.

Advanced Imaging Technology

The Newtom 5G captures a series of 360 images in a single 18-second scan and stores them as digital information in a database on the local server. The software then reconstructs these 2D images into a 3D volume which contains primary images in multiple axial planes. This captured data provides the highest quality images possible for use in diagnosis and treatment planning of the maxillofacial region.

Newtom 5G

The multiple field of view, coupled with the very small 0.3mm focal spot of the Newtom 5G means that the highest quality images can be acquired and reconstructed with great accuracy. All measurements taken are 1:1. The volume of image data captured is also kept to a minimum. This translates into very short image reconstruction times, generally averaging about 60 seconds, and economical disk drive usage.

Newtom 5G

Multiple Scan Modes

The NewTom 5G has five selectable FoV's.

Horizontal Patient Positioning and Pass Through Gantry

The ergonomic, two stage patient chair on the NewTom 5G allows the patient to be seated initially and the moved comfortably into a supine position before being introduced into the scanner to perform the diagnostic examination.
Fine tuning of the patient position can also be carried out through the software before the scan is initiated.

Newtom 5G

Newtom 5G

Newtom "Safe Beam" Technology

Along with the other Newtom systems, the 5G also employs 'Safe Beam' technology which automatically adjusts the radiation dosage according to the patient's age and size. This technology utilizes intermittent bursts of radiation only milliseconds in duration during image acquisition and not the constant radiation stream typical of many other CBCT imaging products. The patient's exposure to radiation is far less than that of competing systems and significantly less than traditional CT scans. Children, for example, receive up to 40% less radiation than adults during a typical scan.

Ask us about the Newtom 5G today and discover the latest technology in medical imaging

Presentations

Please click on the links below to view the corresponding presentations.

Cone Beam CT - Much More than Just Dental Imaging

Prof John Magnussen - Sydney Australia
21 Minutes 26 Seconds

Click here to view presentation


Cone Beam of the Wrist - Better Bony Resolution than MDCT, Lower Dose than Plain Film

Prof John Magnussen - Sydney Australia
17 Minutes 54 Seconds

Click here to view presentation


Newtom 5G - Scan of a Nose Fracture 8x8cm's

Prof Dr Sönke Godbersen - Kiel Germany
4 Minutes 34 Seconds

Click here to view presentation


Newtom 5G - Scan of Airway 18x16cm's

Prof Dr Sönke Godbersen - Kiel Germany
4 Minutes 37 Seconds

Click here to view presentation


Newtom 5G - Scan of Temporal Bone 8x8cm's

Prof Dr Sönke Godbersen - Kiel Germany
4 Minutes 18 Seconds

Click here to view presentation

Specifications

X-ray SourceHF, Constant potential (DC), rotating anode: 110kV; 1-20mA (pulsed)
Focal Spot0.30mm (IEC 336) in standard mode, 0.15mm in zoom mode
X-Ray Cone BeamProprietary "Safe Beam" technology reduces radiation based on patient size.
Field of View (Standard Res, low)18cm x 16cm, 15cm x 12cm, 12cm x 8cm, 8cm x 8cm.
Field of View (Standard Res, boosted)18cm x 16cm, 15cm x 12cm, 12cm x 8cm, 8cm x 8cm.
Field of View (Standard Zoom)12cm x 8cm, 8cm x 8cm, 6cm x 6cm.
Field of View (Hi Res Zoom)12cm x 8cm, 8cm x 8cm, 6cm x 6cm.
Field of View (Ultra Hi Res Zoom)8cm x 8cm, 6cm x 6cm.
Reconstruction Time60 seconds, typical
DoseApproximately 50uSv to 100uSv depending on patient size
Image Acquisition360 Images through 360 degrees of rotation
Image DetectorAmorphous silicon flat panel, 20cm x 25cm
Signal Grey Scale14 bit
Voxel0.30mm minimum cubic isometric, 0.15mm minimum in high resolution zoom mode
Scan Time18 seconds
Patient PositionHorizontal
Patient SupportElectrically controlled patient chair
Max Patient Weight160kg
WeightScanner unit: 530kg
DimensionsScanner : 185cm x 85cm, Patient Aperture : 58cm
Power Required10A @ 100/115V~, 5A @ 200/215/230/240V~, 50/60Hz